Basic Info.

Model NO.
WD-FDZ-028
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Power Source
AC380V
Display Type
Analogue and Digital
Customized
Customized
After-Sales Service
for Ever
Testing Part
Stators
Testing Items
Hi-Pot, Surge, Resistance, Direction
Working Station
2
Transport Package
Ply-Wooden Case
Trademark
WEDE
Origin
Changzhou, China
HS Code
9031809090
Production Capacity
100PCS/Year

Product Description

This stator testing machine is controlled by IPC, displayed by VGA 19". Hi-pot, insulation resistance, cold resistance, in-turns insulation, field rotation direction can be programmed. It fits for max 4 speed single phase motor stator test; cycle time is about 8 seconds.
The system switch-over takes use of imported high voltage relay, hi-pot, in-turns test voltage can be manual adjusted. This system obtains high stability and precision.
Computer collects, records, saves, displays, statics, prints every testing data and result, and supplies users convenient, flexible and visible software. System is composed of measuring and hardware checking software one set each.
The testing items in detail are as follows, 
1. Hi-pot
2. Insulation resistance
3. Cold-resistance (max 5 sections) 4. In-turns insulation (A phase, B phase, C phase or AB phase) 5. Field rotation direction
Testing term: 0~3000V adjustable, AC50HZ
Time: 1~60s, settable
Voltage precision: ±5%
Current range: 0.1mA~10mA
Current precision: 0.1 mA~1mA ±3%; 1 mA~10mA ±1%
Alarm set-up: any point in the range.
Testing term: DC500V
Range: 10MΩ~500MΩ
Testing precision: ±3%
Threshold value set-up: any point in the range.
Testing term:   DC 2 mA / 20mA / 200mA
Resistance range: 10Ω /100Ω /1000Ω
Resistance precision: ±1%
Threshold set-up: any point in the range
Testing term:   DC 0~4000V adjustable, (voltage set-up by customer)
Voltage precision: ±5%
Precision: distinguish 1‰ turn in short circuit.
Testing term: 3 phases 50VAC
Threshold value set-up: CW, CCW



 
2 Stations Wound Stator Testing Machine